Written by Fred Buser
|
|
Thursday, 09 August 2007 |
|
 Fan Center/Thermostat Connections The LDJ A-Maize-Ing Heat furnace operates just like any other natural gas, LP or fuel oil furnace. The burn system on the furnace is controlled by the thermostat in your home. When there is a call for heat, the augers feed fuel to the burn pot. When the heat exchanger reaches temperature, the room air blower operates to heat the home. When the thermostat is satisfied, the augers shut down and the system goes into low idle fire mode.The furnace is made as a stand alone system, but it can be connected into the plenum of your existing furnace as well. Each LDJ furnace is equipped with a 3 speed, 1/2 hp room air blower to force air throughout your home. Plus, each system is ready to operate your air conditioning during the summer months. There is no additional wiring required. To ensure proper operation and functionality, the LDJ A-Maize-Ing Heat furnace must be professionally installed by an HVAC contractor or certified dealer. Improper installation can cause inadequate heating and possible heat exchanger failure. If you or your installer have any questions about installing an LDJ furnace, please contact our technical department.
Technical Furnace Specifications
|
| Power | 120 Volt | 120 volt | | Max Fuse Size | 15 amp | 15 amp | | UL Listed | Yes | Yes | | Dimensions | 53"H x 27"W x 46" D | 53"H x 27"W x 46" D | | Weight | 440 lbs
| 440 lbs
| | Hopper Dimensions | 48"H x 36"W x 52"D | 48"H x 36"W x 52"D | | Hopper Capacity | 14 bushel | 14 bushel | | Hopper Weight | 50 lbs | 50 lbs | | Unit Space Needed | 7' x 7' Area | 7' x 7' Area | | Heat Exchanger | Welded Steel | Welded Steel | | Water Capacity | NA | NA | | | | | | Top Clearance | 32" | 32" | | Side Clearance | 6" | 6" | | Rear Clearance | 18" | 18" | | Front Clearance | 30" | 30" | | Bottom Surface | Must set on a non combustible surface | Must set on a non combustible surface | | | | | | Flue Connection | 6"Φ | 6"Φ | | Min Flue Clearance | 18" | 18" | | Flue Material | Must be 6" round black chimney Pipe | Must be 6" round black chimney Pipe | | Chimney | Must be 6" round Class A All Fuel | Must be 6" round Class A All Fuel | | | | | | Air Filter | 20x20x1 | 20x20x1 | | Supply Air Opening | 18"x 14" | 18"x 14" | | Return Air Opening | 18"x 14" | 18"x 14" | | Minimum Air Flow Required | 850 cfm | 1400 cfm | | Indoor Blower | 1/2 HP 3 Speed | 1/2 HP 3 Speed | | | | | | Input BTU | 100,000 btu | *80,000 - 165,000 btu | | | *Manually Adjustable Variable btu Timer | |
|
Last Updated ( Friday, 10 October 2008 )
|